WASHER LOCK Type | 098197-10

General Details

Status Active
Substitute Part Number
Variant Description n/a

Download Area / Documents

Where Part is Used

Item No. Qty Per Product Number Product Description Type Other Info Markets Product Status Last Date of Manuf. Diagram
165 1 5045K H.D.ROT.HAM.KIT 2 LX Discontinued 12/07/2007 go to diagram
165 1 5045K H.D.ROT.HAM.KIT 2 GB Discontinued 12/07/2007 go to diagram
176 1 AR778A RATCHET 2 LX Live go to diagram
176 1 AR778A RATCHET 2 GB Live go to diagram
165 1 AST6XC ANGLE GRINDER 2 LX Discontinued 12/07/2007 go to diagram
165 1 AST6XC ANGLE GRINDER 2 GB Discontinued 12/07/2007 go to diagram
165 1 AST6XC ANGLE GRINDER 2 GB Discontinued 12/07/2007 go to diagram
165 1 D25899K DEMOLITION HAMMER 3 XJ Discontinued 31/07/2010 go to diagram
165 1 D25899K DEMOLITION HAMMER 2 XJ Discontinued 01/06/2010 go to diagram
165 1 D25899K DEMOLITION HAMMER 1 XJ Discontinued 03/10/2003 go to diagram
6 2 D28700 CHOP SAW 1 item 73 changed to -01 and this spindle has flats on it so also need to change blade flanges to suit GB Discontinued 01/02/2011 go to diagram
6 2 D28700 CHOP SAW 1 item 73 changed to -01 and this spindle has flats on it so also need to change blade flanges to suit LX Discontinued 01/02/2011 go to diagram
6 2 D28715 CHOP SAW 1 Type 2 unit may be removing soft start - field will only have 2 leads instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. GB Discontinued 29/03/2007 go to diagram
6 2 D28715 CHOP SAW 1 Type 2 unit may be removing soft start - field will only have 2 leads instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. LX Discontinued 29/03/2007 go to diagram
6 2 D28715 CHOP SAW 2 A9 market deleted at request of douglas lim (Windchill = Development only) TDR REMOVAL (VI) - email 22-08-2013 may be removing soft start - New field will only have 2 longer leads wired directly into switch instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. For new field with 2 leads items 101,121 and 125 can be discarded and new field wired directly into switch B5 - Discontinued via 2017 global NOD list = 17-11-17 GB Live go to diagram
6 2 D28715 CHOP SAW 2 A9 market deleted at request of douglas lim (Windchill = Development only) TDR REMOVAL (VI) - email 22-08-2013 may be removing soft start - New field will only have 2 longer leads wired directly into switch instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. For new field with 2 leads items 101,121 and 125 can be discarded and new field wired directly into switch B5 - Discontinued via 2017 global NOD list = 17-11-17 LX Live go to diagram
69 2 D28730 CHOP SAW 1 GB Live go to diagram
69 2 D28730 CHOP SAW 1 LX Live go to diagram
30 1 D51822 CLIPPED HEAD FRAMING NAILER 1 NOD 11-036 XJ Discontinued 04/05/2010 go to diagram
108 1 DCG4610T2 ANGLE GRINDER 1 DCG414 TYPE 3 WITHOUT GUARD AND WITH 5" CONCRETE GUARD GB Live go to diagram